Add to Cart
The deionized water purification system in the disinfection and supply room is composed of multiple water treatment unit. The water purification system is based on the raw water quality report provided by the user. We has purposefully and systematically designed a complete set of treatment processes. After introducing membrane separation technologies such as ultrafiltration and reverse osmosis, it provides a very simple and reliable method for the preparation of pure water and large infusion of pharmaceuticals.
Technical Parameter
Model | OK-J500 |
Output(L/h) | 500 |
AC Voltage | 380V,50Hz |
Power(KW) | 4 |
Feed Water Requirement |
tap water: temperature 5~45℃, pressure0.1-0.4Mpa; conductivity<400μs/cm |
Water Quality |
Conductivity: ≤5μs/cm, meets the relevant standards of disinfection supply center in the health industry. |
Water Flow | 3.5-8L/min |
Bacterial Removal Rate | >99.6% |
Total Organic Carbon |
<10ppb |
Heavy Metal |
<0.01 mg/l |
Micro Particles |
>0.2um<1pcs/ml |
Dimension(L*W*H-mm) |
1100*600*1400 |
Weight(kg) |
420 |
Product Feature